Version date 19-12-2023
www.opple.com
LED Batten EcoMax

L W

H
L

Item Code Model Name CCT (KG) L (mm) W (mm) H (mm) (V~) (Hz) Current (A) Rated Power(W)

531000019900 LEDBatten-E L12 19/38W 3000K/4000K 1.36 1128 63 74 220-240 50/60 0.09/0.17 19W/38W

531000020000 LEDBatten-E L15 24/48W 3000K/4000K 1.59 1410 63 74 220-240 50/60 0.12/0.22 24W/48W
531000020100 LEDBatten-E L12 19/38W EM1 3000K/4000K 1.54 1128 63 74 220-240 50/60 0.09/0.17 19W/38W

531000020200 LEDBatten-E L15 24/48W EM1 3000K/4000K 1.77 1410 63 74 220-240 50/60 0.12/0.22 24W/48W

531000020300 LEDBatten-E L12 19/38W DALI 3000K/4000K 1.4 1128 63 74 220-240 50/60 0.09/0.17 19W/38W
531000020400 LEDBatten-E L12 19/38W DALI EM1 3000K/4000K 1.58 1128 63 74 220-240 50/60 0.09/0.17 19W/38W

531000020500 LEDBatten-E L15 24/48W DALI 3000K/4000K 1.63 1410 63 74 220-240 50/60 0.12/0.22 24W/48W

531000020600 LEDBatten-E L15 24/48W DALI EM1 3000K/4000K 1.81 1410 63 74 220-240 50/60 0.12/0.22 24W/48W

Storage Application
Item Code Model Name Lumen Efficacy IP IK Environmen Temperature
Total (lm) (lm/W) Grade Grade (°C) (°C)

531000019900 LEDBatten-E L12 19/38W 2850/5700 150 IP20 IK06 -30~50 -20~45
531000020000 LEDBatten-E L15 24/48W 3600/7200 150 IP20 IK06 -30~50 -20~45

531000020100 LEDBatten-E L12 19/38W EM1 2850/5700 150 IP20 IK06 -30~50 0-40

531000020200 LEDBatten-E L15 24/48W EM1 3600/7200 150 IP20 IK06 -30~50 0-40

531000020300 LEDBatten-E L12 19/38W DALI 2850/5700 150 IP20 IK06 -30~50 -20~45
531000020400 LEDBatten-E L12 19/38W DALI EM1 2850/5700 150 IP20 IK06 -30~50 0-40

531000020500 LEDBatten-E L15 24/48W DALI 3600/7200 150 IP20 IK06 -30~50 -20~45

531000020600 LEDBatten-E L15 24/48W DALI EM1 3600/7200 150 IP20 IK06 -30~50 0-40

Light Source

Item Code Model Name N Energy Label Light source code QR Code

531000019900 LEDBatten-E L12-19/38W-830/840 1

531000020100 LEDBatten-E L12-19/38W-830/840-EM1 1
LS098003832
531000020300 LEDBatten-E L12-19/38W-DALI-830/840 1
531000020400 LEDBatten-E L12-19/38W-DALI-830/840-EM1 1

531000020000 LEDBatten-E L15-24/48W-830/840 1

531000020200 LEDBatten-E L15-24/48W-830/840-EM1 1
LS098004832
531000020500 LEDBatten-E L15-24/48W-DALI-830/840 1

531000020600 LEDBatten-E L15-24/48W-DALI-830/840-EM1 1

1 2

Pagina 2

Ceiling Mounting

3

Min.18mm

Min.45mm

4

L LL L1
L1 E
L E D+ L NE D+

E N D- E N D-
N
N
LEDBatten-E L12-19/38W-830/840 LEDBatten-EL12-19/38W-DALI-830/840 LEDBatten-EL12-19/38W-830/840-EM1 LEDBatten-EL12-19/38W-DALI-830/840-EM1
LEDBatten-E L15-24/48W-830/840 LEDBatten-EL15-24/48W-DALI-830/840 LEDBatten-EL15-24/48W-830/840-EM1 LEDBatten-EL15-24/48W-DALI-830/840-EM1

Access 3 × 1.0-2.5mm cable Access 5 × 1.0-2.5mm cable Access 4 × 1.0-2.5mm cable Access 6 × 1.0-2.5mm cable

Ø8-Ø12mm Ø10-Ø14mm Ø8-Ø12mm Ø10-Ø14mm

5 6

Pagina 3

最新得版本我们增加了CCT-Switch得快接头,

Optional Output 需要再说明书里体现。

CC ON/OFF C DALI
T Seect CT S e
on ection

P ower
Selecio
Pow erS n
elcion

Power Selection Power Selection

L1.2M ON/OFF L1.5M ON/OFF L1.2M DALI L1.5M DALI CCT Selection

N 2 N 2
O 38W O 48W 38W 19W 48W 24W 4000K 3000K
1 1

2 2
O O
1 1
28W 35W

N 2 N 2
O 1 O 1

N 219W N 2 24W
O 1 O 1

PS :The default appearance power is set to the maximum value, and color temperature is set to 4000K

2 N
1

N
E

Max luminairesMax luminaires L
Item Code Model Name connectedin line connectedin line
using e2ternalusing e2ternal
1.5mm wire 2.5mmwire
531000019900 LEDBatten-E L12 19/38W 20 30 the type of the through wiring shall
berubber with nominal crosssectional
531000020000 LEDBatten-E L15 24/48W 20 30 areanot less than 1.5mm Rubber wire

531000020100 LEDBatten-E L12 19/38W EM1 20 30 or PVC wire and it shall passthrough
the knock out hole near theterminal
531000020200 LEDBatten-E L15 24/48W EM1 20 30 block for power supply..

531000020300 LEDBatten-E L12 19/38W DALI 20 30
531000020400 LEDBatten-E L12 19/38W DALI EM1 20 30

531000020500 LEDBatten-E L15 24/48W DALI 20 30

531000020600 LEDBatten-E L15 24/48W DALI EM1 20 30

Emergency

Indicator light is on during battery charging period. Press the testing button to switch to emergency
mode. Indicator light will be off in emergency mode.

Item Code Model Name Battery EM Output (lm) EM Power (W) / Time (H) Battery Model

531000020100 LEDBatten-E L12 19/38W EM1 3.2V/3000mAh LiFePO4 600 5/1.5 EEC110M

531000020200 LEDBatten-E L15 24/48W EM1 3.2V/3000mAh LiFePO4 600 5/1.5 EEC110M

531000020400 LEDBatten-E L12 19/38W DALI EM1 3.2V/3000mAh LiFePO4 600 5/1.5 EEC110M

531000020600 LEDBatten-E L15 24/48W DALI EM1 3.2V/3000mAh LiFePO4 600 5/1.5 EEC110M

Pagina 4

Emergency lighting versions
RECOMMENDED ROUTINE TEST PROCEDURE

The following test is designed to ensure the continued protection of your premises and occupants. Because of the possibility of a failure of the normal
lighting supply occurring shortly after a period of testing, all tests should whenever possible, be undertaken at times of least risk, e.g. during daylight
hours.
ONCE A DAY

Visual inspection of battery charge LED.
ONCE A MONTH
Each unit should be energized from its battery for about 15 minutes by simulation of a failure of the normal lighting supply to ensure the LED’s operate
in the emergency condition.

ONCE A YEAR
Each unit should be energized from its battery for the full rated duration. Inspect the LED’s and if any of them have failed the whole unit will need to be
replaced. The LED’s will probably continue to operate for approximately 5 years but batteries will require replacement every 3 years.
Test method Indicator licht is on during battery charging period, press the testing button to switch to emergency modeindicator light will be extinquished

in emergency mode

SPECIFICATION Battery replacement
1. Working temperature is shown on the table The installation must be carried out by our service agent or a certified
2. Supply: AC220-240V, 50/60Hz, electrician

3. Replaceable fuse: Non 1. Use the tool, open the luminaire.
4. IP Rating:IP20, suitable for indoor use 2. Remove the battery lead connector.
5.Rechargeable LiFePO4 battery (Battery capacity is shown on the 3. Loosen the two screws holding the battery and remove the battery.
table) 4. Replace the new battery and fix it with screws.

6. Emergency time is shown on the table 5. Insert the battery lead connector.
7. Emergency mode: Lamp intensity after 1.5h: >90% of max value in 6. Check the operation, restore A.C power supply, At this time, the
emergency mode battery is charging,, and the LED indicator is "on".; Press the test
8. Color rendering index: >80 for all mode. switch, switch to the emergency state, the indicator LED "off", while the

emergency LED light.
7. Close the luminaire cavity and fix it with tools.
8. Restore AC power supply, and check the operation of LED on the
mains and maintenance version.

Application Environment

1. Suitable for indoor installation to avoid false triggering due to external factors such as rain, wind or tree swing.
2. Shall not be installed in the place with all four metal shelters and small space (such as galvanized-iron roof).
3. Shall note be mounted installation, so as to avoid false trigger caused by the lamp itself shaking.
4. Shall not be installed next to large operating machines such as ventilator/ceil-ing fan to avoid false triggering caused by machine vibration.

Caution: Any operation on LED module is forbidden while power-on.
Zur Vermeidung von Risiken müssen defekte Leitungen ausschließlich vom Hersteller, lnverkehrbringer
oder Fachmann ausgetauscht werden.
Achtung: In betrieb ist keine Arbeit am LED-Modul erlaubt.
For non-user replaceable light sources:
The light source contained in this luminaire shall only be replaced by the manufacture or his service agent

or a similar qualified person.
Für nicht vom Benutzer austauschbare Lichtquellen: IP20 850°C IK06
Die in dieser Leuchte enthaltene Lichtquelle darf nur vom Hersteller oder seinem Servicevertreter oder
einer ähnlich qualifizierten Person ausgetauscht werden.
For use in environments where normal non-conductive/conductive dust accumulation
may be expected, not for use inenvironments with expected high/unusual dust accumulation.
Zur Verwendung in Umgebungen, in denen mit normaler nichtleitender/leitender
Staubansammlung zu rechnen ist, nicht zur Verwendung in Umgebungen mit zu
erwartender hoher/ungewöhnlicher Staubansammlung.

Data subject to change OPPLE Lighting Co., Ltd. Opple Lighting B.V.Meerenakkerweg 1-07
Les données sont sujettes à modifications Room 411, Building 1 No. 6111,Longdong Avenue, Pudong New 5652 AR Eindhoven The Netherlands
Änderungen vorbehalten District, Shanghai City 201201,P. R. China [email protected] www.opple.com

Alle handleidingen en datasheets van Opple